The deck crane fault was located and repaired, and the damaged socket was renewed.
Work Carried Out
- Fault diagnosis
- Replacement of the damaged socket
- Crane operation test
Job Details
The deck crane intermittently lost control signals and stopped unexpectedly. The electrical circuit was measured step by step and the fault was traced to a multi-pin socket in the control line.
Moisture, corrosion and loose pins were found in the socket. It was replaced with a new one, cable ends were re-terminated pin by pin and the connection sealed against water ingress.
After replacement every control function was tested individually, including hoisting, slewing, luffing and the emergency stop circuit.
Checks Performed
- Continuity and insulation measurement
- Control functions
- Emergency stop and limit switches
Outcome
The intermittent fault was eliminated and the crane operates reliably.