The source of a fault in the hatch cover hydraulic system was inspected and identified on site.
Work Carried Out
- On-site system inspection
- Hydraulic circuit check
- Fault report and recommended solution
Job Details
We attended the vessel after reports that the hatch covers opened slowly and stuck during movement. The hydraulic circuit, cylinders and control valves of the cover system were inspected on site.
Pressure readings, cylinder internal-leak checks and valve function tests narrowed down the source of the fault. Hoses, fittings and mechanical hinge points were also reviewed.
Findings and the proposed solution were reported to the ship operator together with the required parts list.
Checks Performed
- System pressure
- Cylinder internal leakage
- Valve and control function
Outcome
The fault source was confirmed and the correct parts and repair plan defined.